Effect of Acute Heat Exposure on the Pressor Response to a Voluntary Hypoxic Apnea: A Cross-tolerance Study.

dc.creatorSaul, Benjamin
dc.creatorHemingway, Holden
dc.creatorRichey, Rauchelle
dc.creatorMoore, Amy
dc.creatorShokraeifard, Austin
dc.creatorCope, Heidi
dc.creatorYurvati, Albert
dc.creatorCunningham, Rebecca
dc.creatorSmith, Michael
dc.creatorRomero, Steven
dc.creator.orcid0000-0002-7090-1782 (Richey, Rauchelle)
dc.date.accessioned2022-05-10T18:05:26Z
dc.date.available2022-05-10T18:05:26Z
dc.date.issued2022
dc.description.abstractThe pressor response induced by a voluntary hypoxic apnea is exaggerated in individuals with obstructive sleep apnea and is strongly correlated to sympathetic overactivity. Acute heat exposure alters neural control of blood pressure, but its effect on the pressor response to a voluntary hypoxic apnea has never been explored. Therefore, we tested the hypothesis that acute heat exposure would attenuate the pressor response to a voluntary hypoxic apnea, and thereby manifest as a form of physiological cross-tolerance. Eight adults (3 females, 26 +/- 2 yrs) were subjected to passive heat stress (water perfused suit) sufficient to increase body core temperature by 1.2°C. Voluntary hypoxic apneas were performed in duplicate before acute heat exposure (pre-heat) and in recovery when body core temperature returned to ≤ 0.3°C of baseline. Participants breathed gas mixtures varying FiO2 (21%, 16%, and 12%; randomized) for 1 min followed immediately by a 15 s end-expiratory apnea. Beat-by-beat arterial blood pressure (Finometer) and arterial oxygen saturation (finger pulse oximetry) were measured throughout. The pressor response was calculated as a difference between baseline mean arterial pressure and the peak response following each apnea. The change in arterial oxygen saturation during each apnea did not differ from pre-heat to recovery (FiO2 21%, pre-heat 0 +/- 1 % vs. recovery 0 +/- 2 %; FiO2 16%, pre-heat -4 +/- 1 % vs. recovery -4 +/- 2 %; FiO2 12%, pre-heat -8 +/- 3 % vs. recovery -10 +/- 4 %; P = 0.3 for interaction). The pressor response to a voluntary apnea was attenuated in recovery from acute heat exposure across all concentrations of FiO2 (FiO2 21%, pre-heat 19 +/- 8 mmHg vs. recovery 16 +/- 8 mmHg; FiO2 16%, pre-heat 27 +/- 8 mmHg vs. recovery 20 +/- 8 mmHg; FiO2 12%, pre-heat 33 +/- 11 mmHg vs. recovery 27 +/- 13 mmHg; P = 0.02 for main effect of time). These data suggest that acute heat exposure induces a cross-tolerance effect such that the pressor response to a voluntary hypoxic apnea is reduced. Acute heat exposure could improve hypertension in adults with obstructive sleep apnea, secondary to altered chemoreflex function and sympathetic neural control, and provide additional therapeutic options for this population to improve cardiovascular health.
dc.identifier.urihttps://hdl.handle.net/20.500.12503/30957
dc.language.isoen
dc.titleEffect of Acute Heat Exposure on the Pressor Response to a Voluntary Hypoxic Apnea: A Cross-tolerance Study.
dc.typeposter
dc.type.materialtext

Files

Collections